If your indoor air conditioning (Air-conditioning) is spewing hot air, the most probable cause is that the refrigerant has leaked out.

All the same, at that place are a number of other possible reasons that may explain why your air conditioner not bravado cold air but running. See our comprehensive listing of common issues beneath, in society of near likely causes to least likely , to place what your item AC unit may be experiencing, and whether or non the outcome has a DIY solution.

Content Navigation

  • AC Unit Components and How They Piece of work
  • Common Reasons Why Your AC is Blowing Hot Air
    • 1. Most Probable: Refrigerant Leak
    • 2. Thermostat on Estrus Mode
    • 3. Dingy Air Filter
    • 4. Dirty Evaporator Coils
    • 5. Frozen Evaporator Coils
    • 6. Wiring Problems
    • 7. Breaker Switch
    • 8. Least Probable: Damaged Compressor
  • HVAC Checkups

AC Unit Components and How They Piece of work

This gets a little technical, only some of our readers enjoy learning the physics and procedure of how their system works. A brief understanding of the procedure might clarify why a refrigerant leak or other issue will affect cooling – and how it can exist resolved.

How an AC System Works

Throughout this article, we refer to different AC unit components. For your agreement, here is a brief description of each component's function:

  • Fan : Aka the blower fan, it pulls in warm air from a room and pushes out cooled/cold air
  • Evaporator (coil) : Evaporates refrigerant liquid to absorb rut out of the air
  • Compressor : In the outdoor unit of your AC system, it increases the pressure level of refrigerant gas, raising its temperature, so oestrus tin can be "squeezed" out of it
  • Condenser (coils) : Also outside, it releases heat outside and reconverts refrigerant into a liquid
  • Expansion valve : Restricts refrigerant liquid period and drops refrigerant force per unit area

An AC unit contains liquid refrigerant which absorbs the hot air in the domicile with the aid of fans. The refrigerant liquid passes through the evaporator curlicue, which turns information technology into a low-pressure gas. That gas is then compressed, then that its temperature increases. It is sent to the condenser coils where the oestrus is released outside and the refrigerant is turned dorsum into a liquid.

The liquid passes through the expansion valve, dropping to a temperature lower than the room, and it proceeds through the evaporator coils a second time to get cool air that is ejected into the room. This process repeats while the AC unit is on.

This helpful video explains the process only described.

With the nuts covered, why is your AC bravado hot air?

Common Reasons Why Your Air conditioning is Blowing Hot Air

1. Most Probable: Refrigerant Leak

There is a fixed corporeality of refrigerant, aka Freon, in your unit of measurement, so if any of information technology is missing, a professional will know information technology immediately by testing refrigerant pressure with a meter.

The hot air you lot are feeling in your home is likely the upshot of the refrigerant leaking out due to one of the causes listed below. Remember, it is the refrigerant that carries heat out of your domicile. The less refrigerant pumping through the AC organisation, the less heat it can remove. If all the refrigerant leaks out, your AC will accident warm air.

There is no one cause for a refrigerant leak, as information technology could be the result of several mishaps. Here are some potential causes your unit may exist experiencing:

  • Your AC unit of measurement was poorly assembled by the manufacturer. This is less mutual amid master AC brands, simply, of course, no company has a perfect track record.
  • A connection betwixt refrigerant lines and coils may have come loose due to your AC unit's age and how often yous use it. These connections sometimes corrode too. This is especially common in coastal areas with salt spray and where heavy pollution results in "acid rain."
  • Habiliment-and-tear on the external Air-conditioning unit, which can exist the consequence of turning your internal Ac on high immediately after being off for the winter. This is why a central air conditioner frequently "dies" immediately or shortly after the cooling season begins.

How to set up the trouble : Unfortunately, a refrigerant is required to purchase refrigerant and accuse an air workout arrangement with it. Refrigerant can exist unsafe in the hands of a not-professional. Contact your HVAC (heating, ventilation, and air condition) technician for aid. If you don't have an Ac company you lot prefer, utilize our Free Local Quotes service for no-price, no-obligation estimates from licensed, pre-screened Air conditioning contractors in your area.

How to foreclose the problem in the future : Have a HVAC technician regularly check your unit. We suggest scheduling six-month or almanac checkups. Waiting longer than a year can take chances AC unit issues.

2. Thermostat on Heat Mode

tthermostat on heat mode

The reason for your Ac unit's malfunction may be that it is non malfunctioning at all. A simple and mutual fault amidst homeowners is to forget that their thermostats were set on "Rut" in the winter, needing only to be changed to "Cool" for the Ac. D'oh!

How to prepare the trouble : All you demand to exercise is alter the thermostat setting.

How to foreclose the problem in the future : Life gets busy and distractions happen all around. Practical precautions tin assist, such every bit writing yourself a note at the kickoff of the winter to switch the thermostat settings in the jump or summer.

3. Dirty Air Filter

dirty air filter

Air filters are a vital component to the Air-conditioning unit of measurement. If your unit of measurement's filter is dirty, such equally with dander, dust, or debris, the pollutants will greatly reduce the air flowing through the Ac unit.

Less airflow ways less heat passing over the indoor coil and being removed. This results in warm air flowing out of your ducts and grates.

Trying to pull air through a dirty decreases your unit'due south efficiency, slows or stops the cooling process, and, if the filter is not cleaned or replaced, volition shorten your Ac and blower fan lifespan.

How to prepare the problem : Replace or clean the air filter. Most are dispensable. A few tin can be cleaned with balmy detergent and water. If yours is disposable, and you don't have a new filter handy, utilise a nylon brush to brush off a layer of dust and droppings. Do it outside, because information technology's a messy job. Then get a replacement filter the next chance you get.

In either case, there is no need to phone a professional.

How to prevent the trouble in the future : Check on the filter from fourth dimension to time. A regular checkup will aid yous remember to clean the filter when information technology starts getting muddied, and it will help you judge when it is necessary to replace the filter.

iv. Dirty Evaporator Coils

dirty evaporator coil

The hot air may be the result of either or both coils being filthy. If the coils are not cleaned, it inevitably leads to heat assimilation and cooling complications, higher temperatures surrounding the coils and the possibility of the coils freezing.

How to gear up the trouble : You tin can phone call a HVAC professional to clean the coils if y'all prefer, but it would save y'all money making this a DIY project.

Here is a basic list on how to clean the coils yourself:

  • Turn the AC off on your thermostat.
  • Discover the access panel on your internal AC unit and remove the screws/fasteners to take the panel off.
  • Blow compressed air across the coils to remove the larger debris and loose clay. Make sure to blow the air in the opposite direction of the organization's normal airflow. Pro Tip: If using high-pressure level compressed air, direct the air through the fins or at a 90-degree bending to preclude damage.
  • To clean the curlicue, yous tin either employ a castor or a commercial cleaner.

Castor method : Use a soft-bristled brush to avoid dissentious the fins and coils. Utilize the brush to the coils and fins to scrub away the hardened clay.

Product method : Follow the instructions and cautions written on the bottle. Spray the cleaner on the coils equally directed and allow the cleaner to foam until the cleaner and the dirt drain abroad. Reapply the cleaner as much equally the instructions permit or until the coils are spotless.

  • For a visual step-by-pace for cleaning an indoor scroll, see this video .

Cleaning the outdoor gyre is a similar process. First, remove the fasteners belongings on the cabinet, and elevator the cabinet off the unit. You tin can and so utilize compressed air or a hose to remove the dirt and debris. Using a soft brush and cleaner volition improve the cleaning.

How to prevent the problem in the hereafter : Regularly clean or change the air filter. If the air filter gets dirt buildup, the evaporator coil will eventually go muddy.

The outdoor gyre, the condensing coil, should be hosed off periodically. For example, if cutting the grass throws lawn clippings onto the condensing unit, hose them off before they can clog the coil.  If you're comfortable with coil cleaning, there is no need to telephone a professional person.

Information technology is imperative to clean the evaporator curl at least once a yr.

5. Frozen Evaporator Coils

frozen evaporator coil

A dirty AC filter tin besides cause the evaporator coil to freeze. This happens because there is non enough airflow passing the coils to evaporate the condensation that the coils produce during the cooling process.

Another factor is how cold the evaporator gyre becomes. With proper airflow, warm air flowing over it will go along it above freezing. Not enough airflow means the coil will literally get freezing cold and the condensation on it will freeze.

When the coil is frozen, it tin't absorb heat out of the air, and the Air-conditioning blowing warm air is the consequence.

How to prepare the problem : Turn the AC off for most an 60 minutes or 2 so that the evaporator coils can thaw out, and clean or replace the filter. You tin also try turning your thermostat to "Fan" mode. This will move warm air over the curl without the Air-conditioning function on. The warm air volition speed up the thawing procedure.

If the filter is cleaned, the coils should non freeze once again. However, if the coils do end upwards freezing a 2nd time, it may exist due to an internal problem with your AC unit. In this example, contact a HVAC technician for farther inspection and help.

How to prevent the problem in the time to come : Regularly clean your AC filter and indoor coil, and keep your thermostat on auto around 70 to 72 degrees Fahrenheit during the starting time few weeks you use the AC in the warmer seasons.

half-dozen. Wiring Issues

There may be frayed, cut, or damaged wires among your internal or external AC unit of measurement. If this is the instance, the AC arrangement will perform poorly and might break downward.

Your unit's malfunction may be the effect of a wire being frayed from overheating; however, this is a rare occurrence. Usually, house pets chew on the internal unit wiring if it is exposed, or an outside creature, such equally a mouse, chews on the external unit of measurement's wiring.

How to fix the problem : If the blanket around the wires is missing, you may be able to salve the wires by wrapping electrical tape effectually the unprotected areas. This should be a short-term fix. It volition be in your best interest to contact a professional person to supersede them.

How to prevent the trouble in the future : For the internal unit, it would be wise to cover the wiring with split plastic tubing similar this designed for the purpose. Until you go the tubing, elevate exposed wires from a pet's achieve.

For the external unit of measurement, building a solid fence around it will likely deter animals from going near or tampering with the wiring.

vii. Breaker Switch

The internal and external Ac units have their own circuit breakers that trip (that is, shut off) if there is a disconnect in the electric current, which is known as a short circuit. The breakers close off as a safety precaution since a short circuit could otherwise crusade a fire.

If the breaker trips for the external Air conditioning unit, your internal unit will withal power on, but it will non be able to cool the hot air it sucks up.

How to fix the trouble : Go to your fuse box and switch the billow "on." If you do not know which billow to look for, information technology is unremarkably the simply one in the grouping switched off.

If the breaker does not stay in the "on" position, or if the ability for the AC unit of measurement does not return once the breaker is switched, then your unit of measurement is likely damaged or experiencing an electrical outcome. To resolve this, contact a HVAC technician or an electrician.

How to forestall the problem in the future : AC units require a lot of energy and can hands trip breakers. To foreclose this, contact a HVAC technician or an electrician to see if your billow can handle your Ac system's current draw.

8. To the lowest degree Probable: Damaged Compressor

The compressor is at the centre of the Air conditioning process; if it fails to work, then the entire procedure collapses. The compressor's breakup is typically the consequence of another underlying consequence. For this reason, be prepared to observe other damaged areas in your Air-conditioning unit.

Unfortunately, a number of things can crusade the compressor to malfunction:

  • Dirty condenser coils . This is when dirt builds upwardly on the coils, preventing them from transfering the heat to the exterior. The system is forced to constantly run in order to cool down, which is taxing on the compressor and causes it to fail.
  • Blocked refrigerant lines . If the refrigerant lines are blocked, the increased pressure level and temperature volition harm the compressor.
  • Refrigerant leaking . If this substance leaks, there will be less of information technology flowing through the lines. This ways the compressor will take to work harder, which will somewhen break it down.
  • Electrical problems . If your Air-conditioning unit experiences electrical issues, it can issue in acid buildup, damaging the compressor. Unfortunately, y'all may find other areas of your Air conditioning unit of measurement being damaged from the buildup.
  • An inadequate amount of oil lubricant . The Air-conditioning unit will not work adequately if it is not lubricated enough. Near bearings used today are sealed, and so cannot be lubricated. If your AC is actually old, this might be an issue.
  • Anomalies, such as manufacturing or installation mistakes . If the manufacturer assembled your AC unit of measurement poorly, some of the mistakes tin can cause overt and unnecessary stress on the compressor. For instance, if your refrigerant lines are likewise large or small for your system, then your compressor will have a shorter lifespan. Also, quality installation is vital to a organisation's longevity. Get estimates from several air conditioner installers, and choose i with a record of quality installation. Our Free Local Quotes is a quick, user-friendly way to starting time the process.

How to fix the problem : Sadly, the compressor cannot exist fixed and requires an proficient center to determine what is breaking it downwardly. In other words, at that place is no way a DIY projection tin be made out of this.

If y'all doubtable the compressor is the reason your Air-conditioning unit is spewing hot air, contact an HVAC professional to diagnose the problem. No matter what the underlying crusade is, however, expect one of the post-obit outcomes to happen:

  • You must supercede the compressor.
  • You must supercede the unabridged exterior condensing unit.
  • You must supersede the condensing unit and the evaporator coil.
  • You lot must replace the entire HVAC system.

How to foreclose the trouble in the future : You can remainder assured, as the reason this falls final on our list is because it does not often occur. This said, we do advise starting the post-obit procedures to prolong the compressor's lifespan:

  • Clean the air filters and so that no pollutants touch on your HVAC organization or hinder the airflow.
  • Clean the system's air ducts then that there is no buildup.
  • Schedule a HVAC system maintenance checkup.

HVAC Checkups

As mentioned throughout this article, the nigh surefire fashion to avert almost of these bug is by arranging inspections with your HVAC technician. We propose waiting no longer than a year for each inspection, every bit you lot may otherwise risk severe problems with your AC organization, which will cost you more than having regular inspections.

You might also void your warranty! That'south something nigh homeowners don't know virtually warranties. Most companies require regular maintenance to go on the warranty intact.

HVAC technicians will give you an understanding of your AC unit's condition and lifespan past testing the unit'south moving parts and checking on the refrigerant, while also locating and repairing any damages that may be.